Salamone, Jerome J. (Committee chair)
Hanesian, Deran (Committee member)
Perna, Angelo J. (Committee member)
Date:
1970-06
Keywords:
Gases -- Absorption and adsorption
Hydrochloric acid
Availability:
Unrestricted
Abstract:
A study was made of the absorption of hydrogen chloride from air mixtures containing from 1 to 40 mgm. HCl/liter (1000 to 40000 mgm./m.3), using a.4" diameter tower packed with 2" Intalox saddles, irrigated with water or with sodium hydroxide solutions of 0.3% to 3.8% concen¬tration. Gas flow rates of 177 to 752 lbs./(hr.)(ft.2) were investigated at three liquid rates: 2960 ; 4260, and 5700 lbs./(hr/)(ft.2). All data were collected below the flooding point.
Correlations of the height of a transfer unit with the superficial gas velocity were prepared for water and for sodium hydroxide irrigation, and a relationship was presented for the over-all coefficient of mass transfer to the ratio of sodium hydroxide normality and pressure. Height of a transfer unit is approximately 0.5 foot for a superficial gas velocity of 500 lbs./(hr.)(ft.2) for both water and sodium hydroxide as absorbing liquid.
If you have any questions please contact the ETD Team, libetd@njit.edu.