Articles via Databases
Articles via Journals
Online Catalog
E-books
Research & Information Literacy
Interlibrary loan
Theses & Dissertations
Collections
Policies
Services
About / Contact Us
Administration
Littman Architecture Library
This site will be removed in January 2019, please change your bookmarks.
This page will redirect to https://digitalcommons.njit.edu/theses/425 in 5 seconds

The New Jersey Institute of Technology's
Electronic Theses & Dissertations Project

Title: Automatic detection of qt and related intervals
Author: Gowdar, Divya
View Online: njit-etd2006-055
(xiv, 98 pages ~ 10.9 MB pdf)
Department: Department of Biomedical Engineering
Degree: Master of Science
Program: Biomedical Engineering
Document Type: Thesis
Advisory Committee: Rockland, Ronald H. (Committee chair)
Reisman, Stanley S. (Committee member)
Schesser, Joel (Committee member)
Date: 2006-05
Keywords: Q wave
QT interval
Automatic detection
Availability: Unrestricted
Abstract:

The objective of this thesis is divided into two main sections: The first section comprises of the development of the algorithm for the detection of the Q wave, Tmax afld the Tend to measure the intervals such as QT, QT corrected (QTc), RT, QTmax and RTmax respectively. The second section deals with the analysis of different variabilities including heart rate variability (HRV), QT, QTc, RT, QTmax and RTmax.

Using the R wave points as reference points, the Q wave was detected by using the Differential Threshold Method (DTH). The Tmax was detected by using a search window on the derived signal of ECG starting from the R peak. The Tmax was detected by two different procedures. The first procedure was a combination of two different methods: the Least Squares Method (LSI) and the Threshold Method (TH) and the second procedure was based on the Differential Threshold Method (DTH). Once the points were detected, the relationship between the heart rate variability (HRV) and corrected QT variability along with other variabilities was studied in this research.

The algorithm was validated on ten patients of five minute data segment of paced breathing at 6 breaths per minute and 12 breaths per minute respectively. The algorithm for the detection of the Q wave, T max and the Tend produced an overall success of 99.16% according to automatic verification of accuracy detection and 96.4% based on manual inspection. In this study, the duration of the QT interval was in the range of 450 to 500 milliseconds, which indicated normal duration of ventricular repolarization. The variability plots indicated similarity between HR variability and QT corrected variability.