Articles via Databases
Articles via Journals
Online Catalog
E-books
Research & Information Literacy
Interlibrary loan
Theses & Dissertations
Collections
Policies
Services
About / Contact Us
Administration
Littman Architecture Library
This site will be removed in January 2019, please change your bookmarks.
This page will redirect to https://digitalcommons.njit.edu/theses/403 in 5 seconds

The New Jersey Institute of Technology's
Electronic Theses & Dissertations Project

Title: Doppler ultrasound technique used to determine the blood flow viscosity in the middle cerebral artery of a canine animal model
Author: Ganpath, Raj P.
View Online: njit-etd2006-004
(xvi, 106 pages ~ 12.1 MB pdf)
Department: Department of Mechanical Engineering
Degree: Master of Science
Program: Mechanical Engineering
Document Type: Thesis
Advisory Committee: Aubry, N. (Committee chair)
Singh, Pushpendra (Committee member)
Geskin, E. S. (Committee member)
Date: 2006-01
Keywords: Blood flow velocity
Cerebral artery
Doppler ultrasound
Availability: Unrestricted
Abstract:

The cerebral blood flow velocity in the middle cerebral artery of an canine animal model was measured using the Doppler Ultrasound technique. A transducer was designed with a 20 MHz piezoelectric crystal and used for the application. An in vitro calibration system was designed and machined for the purpose of testing and calibrating every transducer before using it in vivo. Preliminary tests included experiments on the in vitro system and measurement of blood flow velocity in the human wrist artery (metacarpal artery). The effect of using different transmission media (agarose and gelatin) was determined through the many in vitro and animal experiments. A design of surgical preparation and setup which included instrumentation and procedure was developed. The in vivo measures included blood flow velocity in the femoral, left gastric and mesenteric arteries of a mouse (14.5cm/s to 17.4cm/s; 12cm/s to l4cm/s; 25cm/s to 30cm/s respectively), middle cerebral artery (MCA) of a pig (7.5cm/s to 8.5cm/s), the MCA of a dog (5.5cm/s to 6cm/s) and drug response as an indication of instrument sensitivity (increase from 6cm/s to 10cm/s with introduction of Forskolin). The values obtained matched those in the published literature. Fast Fourier Transformations were used to write programs in MATLAB which served as the tool for data analysis.


If you have any questions please contact the ETD Team, libetd@njit.edu.

 
ETD Information
Digital Commons @ NJIT
Theses and DIssertations
ETD Policies & Procedures
ETD FAQ's
ETD home

Request a Scan
NDLTD

NJIT's ETD project was given an ACRL/NJ Technology Innovation Honorable Mention Award in spring 2003