Articles via Databases
Articles via Journals
Online Catalog
E-books
Research & Information Literacy
Interlibrary loan
Theses & Dissertations
Collections
Policies
Services
About / Contact Us
Administration
Littman Architecture Library
This site will be removed in January 2019, please change your bookmarks.
This page will redirect to https://digitalcommons.njit.edu/theses/958 in 5 seconds

The New Jersey Institute of Technology's
Electronic Theses & Dissertations Project

Title: Development and field testing of pulse introduction membrane extraction (PIME) for measurement of ground water contamination
Author: San Juan, Anthony
View Online: njit-etd1998-097
(vii, 60 pages ~ 3.3 MB pdf)
Department: Department of Chemical Engineering, Chemistry and Environmental Science
Degree: Master of Science
Program: Applied Chemistry
Document Type: Thesis
Advisory Committee: Mitra, S. (Committee chair)
Kebbekus, Barbara B. (Committee member)
Venanzi, Carol A. (Committee member)
Date: 1998-08
Keywords: Water pollution.
Membrane separation.
Volatile organic compounds.
Availability: Unrestricted
Abstract:

VOCs are a class of aromatic and aliphatic compounds with a variety of functional groups, and are in general detrimental to human health even at trace levels. Conventional analysis of VOCs in groundwater usually involves sampling at site followed by laboratory analysis. This results in long turn around times, high cost and also errors associated with sample preservation during transportation and storage. In order to address these problems, a field portable instrument referred to as Pulse Introduction Membrane Extraction (PIME) has been developed for monitoring trace level halogenated organic contaminants in ground water. A membrane extraction approach has been used, to selectively extract and concentrate the organics from a complex aqueous matrix with no additional sample preparation, thereby attaining high sensitivity and low detection limits. Using a field portable gas chromatography, analysis of individual discrete as well as continuous on-line monitoring of VOCs in groundwater was performed at a Superfund site. The results of the field test demonstrated that the field-PIME could provide real-time, cost-effective data for site assessment and rapid decision-making. The results from field-PIME analysis were in good agreement with that from a certified reference laboratory. Statistical analysis of this comparative data is also presented.


If you have any questions please contact the ETD Team, libetd@njit.edu.

 
ETD Information
Digital Commons @ NJIT
Theses and DIssertations
ETD Policies & Procedures
ETD FAQ's
ETD home

Request a Scan
NDLTD

NJIT's ETD project was given an ACRL/NJ Technology Innovation Honorable Mention Award in spring 2003