Articles via Databases
Articles via Journals
Online Catalog
E-books
Research & Information Literacy
Interlibrary loan
Theses & Dissertations
Collections
Policies
Services
About / Contact Us
Administration
Littman Architecture Library
This site will be removed in January 2019, please change your bookmarks.
This page will redirect to https://digitalcommons.njit.edu/theses/1146 in 5 seconds

The New Jersey Institute of Technology's
Electronic Theses & Dissertations Project

Title: Time domain and frequency domain analysis of myoelectric signals during muscle fatigue
Author: Maniar, Rakesh M.
View Online: njit-etd1995-018
(xii, 107 pages ~ 4.7 MB pdf)
Department: Biomedical Engineering Committee
Degree: Master of Science
Program: Biomedical Engineering
Document Type: Thesis
Advisory Committee: Reisman, Stanley S. (Committee chair)
Kristol, David S. (Committee member)
Findley, Thomas W. (Committee member)
Date: 1995-01
Keywords: Electromyography
Muscles--Physiology
Availability: Unrestricted
Abstract:

Spectral analysis of the EMG signal is a useful tool for studying the complex phenomena of fatigue. The spectral parameters of mean frequency and median frequency, and the time domain parameter of root mean square have been used to measure localized fatigue.

The normal values of median frequency and its decline with fatigue have not as yet been determined in healthy subjects. This should be done in order to apply spectral analysis for clinical evaluations of abnormal populations. Normal median frequency values and its slope were established in this work for the upper extremity muscles of biceps, triceps and deltoid during a pilot study. The result showed that the triceps has a lower slope value, hence more type I fiber (fatigue resistant) as compared to that of biceps and deltoids. In addition, a monopolar fine wire electrode referenced to a surface electrode was compared with a bipolar surface electrode and bipolar fine wire electrodes in order to test the monopolar fine wire electrode as a technique to measure fatigue. The result showed that the monopolar fine wire electrode measured fatigue more reliably than the surface electrode, Further, for bipolar fine wire electrodes, where the active electrode is proximal to the motor point, the distance between the active electrode and the reference electrode is important in order to measure fatigue reliably.


If you have any questions please contact the ETD Team, libetd@njit.edu.

 
ETD Information
Digital Commons @ NJIT
Theses and DIssertations
ETD Policies & Procedures
ETD FAQ's
ETD home

Request a Scan
NDLTD

NJIT's ETD project was given an ACRL/NJ Technology Innovation Honorable Mention Award in spring 2003