Articles via Databases
Articles via Journals
Online Catalog
E-books
Research & Information Literacy
Interlibrary loan
Theses & Dissertations
Collections
Policies
Services
About / Contact Us
Administration
Littman Architecture Library
This site will be removed in January 2019, please change your bookmarks.
This page will redirect to https://digitalcommons.njit.edu/theses/1671/ in 5 seconds

The New Jersey Institute of Technology's
Electronic Theses & Dissertations Project

Title: Biomechanical comparison of interosseous and subperiosteal flexor tendon reattachment
Author: Olin, Alisa Beth
View Online: njit-etd1994-113
(xi, 67 pages ~ 2.6 MB pdf)
Department: Biomedical Engineering Committee
Degree: Master of Science
Program: Biomedical Engineering
Document Type: Thesis
Advisory Committee: Mayott, Clarence W. (Committee chair)
Kristol, David S. (Committee member)
Parker, Richard Clyde (Committee member)
Date: 1994-01
Keywords: Tendons--Surgery.
Tendons--Mechanical properties.
Availability: Unrestricted
Abstract:

This study was undertaken to biomechanically compare the interosseous and subperiosteal distal flexor tendon reattachment techniques. Twenty New Zealand white rabbits underwent division of the right second and third hind limb profundus flexor tendon distal to the insertion of the superficial flexor. All tendons were repaired using the Kleinnert-Bunnell configuration with a 5-0 nylon tied over a cotton pad on the dorsum of the digit. In half of the animals, the second profundus was reattached into a hole in the middle phalanx and the third profundus was reattached after periosteal stripping of the middle phalanx. The other animals underwent subperiosteal repair of the second flexor and interosseous repair of the third.

The limbs were immobilized for three weeks at which time 10 animals were sacrificed (Group 1), the limb disarticulated and frozen. The remaining (Group 2) were, following an additional five weeks, sacrificed and the limbs harvested and frozen. The limbs were thawed and the repaired tendons biomechanically tested to failure with an Instron, servo-hydraulic mechanical test system.

RESULTS:
  Interosseous Subperiosteal
Group 1 (3 weeks) 17 ± 4 N 15 ± 5 N
Group 2 (8 weeks) 45 ± 16 N 58 ± 19 N

Controls (3 weeks) and controls (8 weeks) produced mean and standard deviation values of 91 ± 16 Newtons and 100 ± 20 Newtons respectively.

These results were analyzed with the ANOVA, Analysis of Variances method. No statistical differences were found between the interosseous and subperiosteal repair sites. It is concluded that both techniques were successful in attaining sufficient healing. The repaired tendon-bone interfaces were capable of withstanding physiologic loads.


If you have any questions please contact the ETD Team, libetd@njit.edu.

 
ETD Information
Digital Commons @ NJIT
Theses and DIssertations
ETD Policies & Procedures
ETD FAQ's
ETD home

Request a Scan
NDLTD

NJIT's ETD project was given an ACRL/NJ Technology Innovation Honorable Mention Award in spring 2003